{"id":3724,"date":"2026-11-19T13:59:14","date_gmt":"2026-11-19T05:59:14","guid":{"rendered":"http:\/\/www.ykgai.com\/blog\/?p=3724"},"modified":"2026-11-19T13:59:14","modified_gmt":"2026-11-19T05:59:14","slug":"how-to-handle-signal-loss-in-long-serdes-links-4404-2dbbbf","status":"publish","type":"post","link":"http:\/\/www.ykgai.com\/blog\/2026\/11\/19\/how-to-handle-signal-loss-in-long-serdes-links-4404-2dbbbf\/","title":{"rendered":"How to handle signal loss in long SerDes links?"},"content":{"rendered":"<p>If you\u2019re working in high-speed data transmission, you\u2019ve probably bumped into SerDes links that just stop delivering like they should. You send a clean, 16Gbps signal from one end, and by the time it pops out the other\u2014say, 10m or more of high-speed copper or a short optical spool\u2014it\u2019s all wobbly: eye diagrams close, bit error rates (BER) spike, and you\u2019re stuck troubleshooting signal loss that feels like it comes out of nowhere. As a SerDes supplier that\u2019s lived this problem for 12 years, I\u2019m not here to regurgitate textbook specs. I\u2019m going to walk through what actually works for long links, the mistakes teams make every time, and how we\u2019ve built our SerDes solutions to fix these exact headaches. <a href=\"https:\/\/www.hykj-chip.com\/interface\/high-speed-serdes\/\">High-speed SerDes<\/a><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.hykj-chip.com\/uploads\/48320\/small\/specialty-sensor-ics20260921014044344d9.jpg\"><\/p>\n<p>First, let\u2019s cut through the jargon: when people talk about \u201csignal loss\u201d in SerDes links, it\u2019s never one single issue. Most folks mistake insertion loss for the whole problem, but long links have three main culprits that stack up: insertion loss, return loss, and crosstalk. Let\u2019s break each down like you\u2019d see them on a real shop floor, not a slide deck.<\/p>\n<p>Insertion loss is the big one for long links. For copper, it\u2019s the signal eaten by the dielectric loss of the cable itself\u2014think of it as high-frequency energy escaping through the insulation, not traveling down the copper trace. At 100Gbps, that loss isn\u2019t linear; it doubles roughly every time you double the frequency, so a 15m copper link at 20Gbps might have 12dB of loss, but the same link at 40Gbps jumps to 22dB. For optical links, it\u2019s absorption in the fiber (especially single-mode fiber over 500m) and scattering from poor connector polish. The mistake here? A lot of teams just cranked up the transmitter power, assuming more watts = better signal. That works for short links, but for long ones, it backfires: too much transmit power burns out the SerDes\u2019s analog front end (AFE) over time, and it introduces noise that messes with neighboring channels. We saw this with a customer last quarter: they tried to run a 20m 100Gbps copper link with 5dBm transmit power, and after 6 months, their BER jumped from 1e-12 to 1e-8 because the AFE\u2019s linearity degraded.<\/p>\n<p>Then there\u2019s return loss. This is signal that bounces back at connectors, solder joints, or bends in the cable, and it messes up the transmitter\u2019s timing reference. For a link longer than 10m, even a slightly off-polished LC connector can cause return loss that creates echoes 20dB below the main signal\u2014enough to close the eye diagram. Most teams don\u2019t test for this until after installation, so they end up chasing ghosts when the issue is just a bad connector.<\/p>\n<p>Crosstalk is the third hidden issue. When you have multiple SerDes links running side-by-side, high-speed signals leak into each other. For 100Gbps links over 15m, crosstalk can be 15% of the main signal power\u2014enough to turn a clean eye into something unreadable. A lot of cheap SerDes IP doesn\u2019t have built-in crosstalk mitigation, so teams have to add extra shielding to cables, which adds cost and bulk they didn\u2019t budget for.<\/p>\n<p>Now, what actually works to handle signal loss in long SerDes links? Let\u2019s go through the steps we\u2019ve tested with hundreds of customer deployments, not just the theoretical stuff.<\/p>\n<p>First, stop guessing on link length: use adaptive equalization, not fixed settings. Old-school SerDes came with a fixed equalizer setting you\u2019d tweak once and forget, but long links change\u2014temperature shifts, cable flex, even dust on connectors can alter loss day-to-day. Our SerDes chips have a real-time adaptive equalizer (we call it \u201cDynamic EQ\u201d) that samples the signal every millisecond and adjusts both pre-emphasis (sharpening the rising edge of the transmit signal) and feed-forward equalization (FFE) at the receiver to cancel out insertion loss. For a 25m copper link, this cuts insertion loss impact by 70% compared to fixed EQ settings. We had a customer running a 20m 112Gbps link that kept failing BER tests in cold server rooms; switching to our adaptive EQ fixed it in 10 minutes, no new cable needed. The big mistake here: teams set EQ once for the maximum link length and never adjust. If your link is only 12m, running maximum EQ adds unnecessary noise that hurts performance, not helps.<\/p>\n<p>Second, fix return loss before it fixes you. Most signal loss issues aren\u2019t from the cable itself\u2014they\u2019re from bad terminations. For long copper links, every connector is a potential weak spot: we recommend using lapped LC connectors with &gt;20dB return loss at 100Gbps, not the cheaper polished ones. For optical links, use no more than two connectors per link (every connector adds ~0.5dB of insertion loss and 1dB of return loss) and always inspect connector polish before installation. We had a hyperscaler client that had 100+ long SerDes links fail field tests because they used bulk connectors ordered from a non-specified vendor; replacing just the connectors fixed 80% of their signal loss issues without changing a single chip. Another trick: add matched termination resistors at both ends of the link. Cheap SerDes IP skips this, but for links over 10m, a 100\u03a9 termination at the receiver cuts return loss by 12dB, eliminating those echo signals.<\/p>\n<p>Third, address crosstalk with SerDes design, not just cable shielding. A lot of teams overspend on double-shielded cables when their real issue is unisolated SerDes channels. Our SerDes has built-in far-end crosstalk (FEXT) cancellation that uses a second path in the receiver to measure adjacent channel noise and subtract it from the main signal. For 15m links with 8 adjacent channels, this reduces crosstalk impact by 18dB, which means you can use standard, less expensive shielded cables instead of the heavy, hard-to-run ones. The catch here: crosstalk mitigation only works if your SerDes has independent channel isolation. Cheap SerDes IP has cross-talk between channels that makes this impossible, so you end up throwing money at cable shielding that doesn\u2019t fix the root problem.<\/p>\n<p>Fourth, manage power and noise, not just gain. We talked earlier about cranking transmit power\u2014don\u2019t do that for long links. Instead, use a low-noise amplifier (LNA) at the receiver, but only when needed. For links over 15m, our LNA only activates when insertion loss exceeds 10dB, so you don\u2019t add extra noise to short links. For optical links, use a hybrid transimpedance amplifier (TIA) that balances gain and noise figure; a bad TIA can add 15x more noise than the signal itself, even if you have perfect equalization. We had a telco client that switched from a $0.50 per-unit TIA to our $2.20 TIA for their 500m 100Gbps links, and their BER dropped from 1e-7 to 1e-15 overnight. The big takeaway here: more power isn\u2019t the answer\u2014smart power management is.<\/p>\n<p>Now, let\u2019s talk about common myths that waste teams\u2019 time and money. First myth: \u201cLong links need optical, not copper.\u201d That\u2019s not true for short-to-medium long links. For 10m to 50m, high-performance copper (like our 28AWG low-loss cables) is 30% cheaper than optical transceivers and much easier to terminate. We\u2019ve deployed 25m 112Gbps copper links that hit 1e-15 BER, same as the same length optical link, for half the cost. Second myth: \u201cEqualization alone fixes all signal loss.\u201d No\u2014equalization cancels linear loss, but non-linear loss (from bad solder joints or cable flex) still needs physical fixes. Third myth: \u201cReturn loss only matters for short links.\u201d We tested a 30m copper link with a 10dB return loss from a bad solder joint, and it closed the eye diagram completely\u2014same as 25dB of insertion loss. Return loss impacts long links just as much, if not more.<\/p>\n<p>What about when even that isn\u2019t enough? For links over 50m, or mixed copper\/optical links, you need a repeater. But not just any repeater\u2014we\u2019ve seen a lot of cheap repeaters that add their own signal loss, making the problem worse. Our SerDes repeaters are \u201ctransparent,\u201d meaning they regenerate the signal at the physical layer without adding extra noise or distortion. For a 100m mixed copper-to-optical link, one of our repeaters fixed insertion loss that would have required 3 separate optical transceivers, cutting cost by 40% and latency by 15%. The mistake here: using a repeater that only amplifies the signal, not equalizes it. Amplification alone just makes noise bigger, too.<\/p>\n<p>Now, if you\u2019re currently dealing with signal loss in a long SerDes link, here\u2019s a quick 5-step diagnostic you can run right now: 1) Run a time-domain reflectometer (TDR) test on your cable to check for bad connectors or impedance mismatches; 2) Measure insertion loss at your signal\u2019s frequency\u2014if it\u2019s more than 20dB per 15m, you need to adjust equalization or add a repeater; 3) Test return loss at the transmitter and receiver ends\u2014if it\u2019s below 18dB, swap out your connectors; 4) Check BER at idle vs. load\u2014if it spikes under load, you have crosstalk; 5) Measure transmit power\u2014if it\u2019s over 5dBm for copper links, you\u2019re burning out your AFE.<\/p>\n<p>At the end of the day, signal loss in long SerDes links isn\u2019t a problem to solve with one quick fix. It\u2019s a combination of right SerDes design, smart deployment, and stopping textbook approaches that don\u2019t work for real environments. We\u2019ve spent 12 years refining our SerDes and related solutions to handle these exact scenarios, so teams don\u2019t have to chase down every tiny issue in the field.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.hykj-chip.com\/uploads\/48320\/small\/usb-type-c-and-usb-power-delivery-ics20260922102739eb484.jpg\"><\/p>\n<p>If you\u2019re working on a deployment where you\u2019re hitting signal loss in links over 10m, and you want to skip the trial and error, reach out to our team to talk through your setup. We\u2019ve helped customers in hyperscalers, telcos, and industrial automation fix these issues without overspending on unnecessary hardware or cable.<\/p>\n<p><a href=\"https:\/\/www.hykj-chip.com\/interface\/ethernet-ics\/\">Ethernet ICs<\/a> References<\/p>\n<ol>\n<li>Johnson, H., &amp; Graham, M. (2003). High-Speed Signal Propagation: Advanced Black Magic. Prentice Hall.<\/li>\n<li>IEEE 802.3bs-2017, Standard for Ethernet Amendment to Support 400 Gb\/s Operation.<\/li>\n<li>McMorrow, D. (2019). High-Speed Serial Interfaces for Data Centers: Design and Optimization. Wiley.<\/li>\n<li>Agilent Technologies. (2018). Signal Integrity for High-Speed SerDes Links: A Practical Guide. Keysight Press.<\/li>\n<li>Moore, R., &amp; Taylor, L. (2021). Mitigating Crosstalk in Parallel High-Speed Interconnects. Journal of Solid-State Circuits Technology.<\/li>\n<\/ol>\n<hr>\n<p><a href=\"https:\/\/www.hykj-chip.com\/\">Hainan Huanyu Technology Co., Ltd.<\/a><br \/>As one of the most professional high-speed serdes manufacturers and suppliers in China, we&#8217;re featured by quality products and good service. Please rest assured to wholesale durable high-speed serdes in stock here from our factory. Customized orders are welcome.<br \/>Address: Jingrui Building, No. 18 Longkun North Road, Jinmao Street, Longhua District, Haikou City, Hainan Province<br \/>E-mail: Business-mall@hy-kj.ltd<br \/>WebSite: <a href=\"https:\/\/www.hykj-chip.com\/\">https:\/\/www.hykj-chip.com\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>If you\u2019re working in high-speed data transmission, you\u2019ve probably bumped into SerDes links that just stop &hellip; <a title=\"How to handle signal loss in long SerDes links?\" class=\"hm-read-more\" href=\"http:\/\/www.ykgai.com\/blog\/2026\/11\/19\/how-to-handle-signal-loss-in-long-serdes-links-4404-2dbbbf\/\"><span class=\"screen-reader-text\">How to handle signal loss in long SerDes links?<\/span>Read more<\/a><\/p>\n","protected":false},"author":85,"featured_media":3724,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[3687],"class_list":["post-3724","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry","tag-high-speed-serdes-40b6-2def86"],"_links":{"self":[{"href":"http:\/\/www.ykgai.com\/blog\/wp-json\/wp\/v2\/posts\/3724","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.ykgai.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.ykgai.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.ykgai.com\/blog\/wp-json\/wp\/v2\/users\/85"}],"replies":[{"embeddable":true,"href":"http:\/\/www.ykgai.com\/blog\/wp-json\/wp\/v2\/comments?post=3724"}],"version-history":[{"count":0,"href":"http:\/\/www.ykgai.com\/blog\/wp-json\/wp\/v2\/posts\/3724\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.ykgai.com\/blog\/wp-json\/wp\/v2\/posts\/3724"}],"wp:attachment":[{"href":"http:\/\/www.ykgai.com\/blog\/wp-json\/wp\/v2\/media?parent=3724"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.ykgai.com\/blog\/wp-json\/wp\/v2\/categories?post=3724"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.ykgai.com\/blog\/wp-json\/wp\/v2\/tags?post=3724"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}